Model NO.: HD25F
Fuel: Gasoline Engine
Trademark: FUNSOR
Transport Package: Export Carton
Specification: CE, EPA and VCA
Origin: Hangzhou, Zhejiang
HS Code: 840721000
China HANGZHOU HIDEA Outboard Engine is the1st brand of China.Hidea owns R&D center, advanced production line, strict testing system and high-efficiency after-sales service system. It cooperates with China First Auto Works Corp. (FAW), who provides capital and technological support. Hidea was approved by ISO9001 international quality system, and won many hornors by its excellent performance and steady quality, such as CE, EPA and VCA certificates.
  Model |     HD25F |
    Max.Output(kw) |     18 |
    Full Throttle Operating Range(rpm) |     4500-5500 |
    Stroke |     2 |
    Cylinder |     2 |
    Displacement(cc) |     496 |
   BorexStroke(mm) |     72 x 61 |
   LengthxWidthxHeight short shaft(mm) |    843 x 399 x 1146 |
    LengthxWidthxHeight long shaft (mm) |     843 x 399 x 1273 |
    Weight (kg) |     S:53 L:54.5 |
    Gear Shift Position |     F-N-R |
    lgnition System |     CDl |
    Cooling System |     Water-cooling |
    Starting System |     Manual & Electric Starter |
    Control System |     Tiller control & front control |
    Lubrcation System |     Gasoline & Machine Oil |
    Regular Gasoline |     50:1 |
    Capacity of Fuel Tank(L) |     24 |
The disposable medical mask is suitable for covering the mouth, nose and jaw of the user, and is used in a general medical environment to wear, block the oral cavity and nasal cavity to exhale or spray contaminants. The bacterial filtration efficiency of the mask should not be less than 95%. Not applicable to medical protective masks and medical Surgical Masks.
The ventilation resistance test takes the center part of the mask for testing. The gas flow for the test needs to be adjusted to (8±0.2) L/min, the diameter of the sample test area is 25 mm, and the test area of the test sample is A. Measure the pressure difference between the two sides of the mask with a differential pressure meter or equivalent equipment, and calculate the ventilation resistance according to the formula ΔP=M/A.
ΔP-the pressure difference per square centimeter area of the test sample, the unit is Pa per square centimeter (Pa/cm³);
M --The differential pressure value of the test sample in Pa (Pa);
A --Test area of test sample, unit is square centimeter.